Product Description
Dri-Ref Reference Electrode, 2 mm (short)
- 2 mm diameter (short)
- Extremely low electrolyte leakage properties
- Stable and reproducible potential
- Low resistance
S$300.00
Dri-Ref™ reference electrodes were developed by WPI to have extremely low electrolyte leakage properties, hence the name “Dri-Ref”. In addition to this key feature, these electrodes exhibit stable and reproducible potential and low resistance. Stored in KCl when not in use, they have a long life expectancy.
Use with ion selective electrodes
Although the internal filling solution contains KCl, the low fluid leakage means Dri-Ref may be used in combination with ion selective electrodes, including those for K+ and Cl-, without significant contamination from the reference electrode.
Chemically resistant
The Dri-Ref electrodes are chemically resistant to strong acids and alkalines. Dri-Ref electrodes are not suitable for use in organic solvents.
| Length | 2cm |
| Diameter | 2mm |
| Construction | Isoplast |
| Lead Length | 30 in. (76cm) |
| CONNECTOR | 2 mm pin |
| Resistance (typical) | ~2.7 KΩ |
| Filling Solution | KCl |
| ELECTROLYTE Leakage (mL/hr) | ~5.7×10-8 |
| Notes: | Isoplast is a trade mark of Dow Chemical. Teflon is a trade mark of DuPont. |
| Length | 2cm |
| Diameter | 2mm |
| Construction | Isoplast |
| Lead Length | 30 in. (76cm) |
| CONNECTOR | 2 mm pin |
| Resistance (typical) | ~2.7 KΩ |
| Filling Solution | KCl |
| ELECTROLYTE Leakage (mL/hr) | ~5.7×10-8 |
| Notes: | Isoplast is a trade mark of Dow Chemical. Teflon is a trade mark of DuPont. |
Item#: TBR4100-416 Real-time detection using electrochemical microsensors Integrated system - includes sensors and start-up kit Measure up to 4 species in the same preparation Wide dynamic range for detection Includes Lab-Trax 4/16
LUER-TO-TUBING COUPLER ASSORTMENT KIT (POLYPROPYLENE) 504954 This Luer coupler kit is useful for building your own liquid flow experiments. The kit are over 250 assorted parts including barbed male Luers of various sizes with locking nuts or slip fits, female Luers for bulkhead mounting in several sizes, female Luer connectors with full Luer threads, threaded port male slip Luers, female…
Block 196 Pandan Loop #06-21,
Pantech Business Hub, Singapore 128384
TEL: +65-6364 0391
Fax: +65 6269 0745
EMAIL: info@test.primebioscience.com
Suite #13-10, Level 13,
Johor Bahru City Square (Office Tower),
106-108, Jalan Wong Ah Fook,
8000 Johor Bahru, Johor, Malaysia
TEL: +607-225 4853
Fax: +607-225 4903
EMAIL: info@test.primebioscience.com
Copyright © 2017 Prime BioScience PTE LTD. All rights Reserved.
Reviews
There are no reviews yet.